08 90 00 Louvers and Vents

Sub-sections in this division:

08 — Openings 08 10 00 — Doors and Frames 08 50 00 — Windows 08 71 00 — Door Hardware 08 80 00 — Glazing

Spec Entries — 3 results across all jurisdictions

City of Henderson Ventilation & Waterproofing View Source ↗

Air Sealing — Blower Door Test Required

Residential units in Climate Zone 3 must achieve 3.0 ACH50 via third-party blower door test. Alternatives: 4.0 ACH50 non-sprinklered, 4.5 ACH50 sprinklered. Qualifying air barriers include: 1/2 in gypsum board, 5/8 in Portland cement stucco, closed-cell spray foam (1.5 in min), and others per IECC C402.6.2.3.1.

IECC R402 / C402 (Climate Zone 3)

07 20 00 07 21 00 07 24 00 08 50 00 08 80 00 09 20 00 09 29 00 09 60 00 09 90 00 21 13 00 34 41 13 34 71 13
City of Henderson Building Utilities View Source ↗

Energy Efficiency — Insulation Minimums (Climate Zone 3)

Ceiling: R-38. Wood-framed wall: R-20 or R-13+5ci or 0+15ci. Floor: R-19 or R-13+5ci or 15ci. Unheated slab edge: none required. Vertical fenestration: max U-factor 0.30, max SHGC 0.25. Skylight: max U-factor 0.53, max SHGC 0.28.

IECC 2024 Tables R402.1.2 and R402.1.3 (Climate Zone 3)

02 32 00 03 20 00 03 31 00 06 10 00 07 20 00 07 21 00 08 50 00 08 80 00
City of Las Vegas Ventilation & Waterproofing View Source ↗

Foundation Waterproofing & Dampproofing

Section R406.2 (foundation waterproofing and dampproofing) is specifically amended for Southern Nevada conditions. When basements are installed, plans must show a cross-section with materials, exterior waterproofing, and egress window well details.

SNBO 2024 IRC Amendment §R406.2; IRC R406

02 32 00 03 20 00 03 31 00 06 10 00 07 10 00 07 25 00 07 31 00 07 32 00 08 50 00 08 80 00 32 16 00 34 71 00